Part Number Hot Search : 
PT7874P 385103 1N5230 GS25U18 KK74A N80C31BH ZVP4105A EPD1006
Product Description
Full Text Search
 

To Download GWKAJRB2EM Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  2012-04-10 preliminary data 1 2012-03-20 preliminary data soleriq e 30 datasheet draft version 0.0 gw kajrb2.em the soleriq? e products were specifically designed for applications requiring large flux packages out of a compact area. die soleriq? e produkte wurden speziell fr anwendungen entwickelt, die gro?e lumenpackete aus einer kompakte fl?che ben?tigen. for the replacement of traditional cfl light sources in downlights the following typical led efficacies can be achieved at 4000 k: 2x18 w 111 lm/w 2x26 w 101 lm/w fr den ersatz von traditionellen cfl-lichtquellen in downlights lassen sich bei 4000 k folgende typische led effizienzen erzielen: 2x18 w 111 lm/w 2x26 w 101 lm/w features: besondere merkmale: ? package: chip-on-board ? geh?usetyp: chip-on-board ? chromaticity coordinate groups: 4 sdcm center ansi box at ts = 85 c ? farbortgruppen: 4 sdcm in der mitte der ansi box bei ts = 85 c ? color: white; cri (typ.) = 85; ctr = 4000 k; cri (min.) = 80 ? farbe: wei?; cri (typ.) = 85; ctr = 4000 k; cri (min.) = 80 ? optical efficiency (typ.): 114 lm/w (white) at 4000 k ? optischer wirkungsgrad (typ.): 114 lm/w (wei?) bei 4000 k ? esd-withstand voltage: up to 2 kv acc. to jesd22-a114-f ? esd-festigkeit: esd-sicher bis 2 kv nach jesd22-a114-f ? viewing angle at 50 % i v : 120 ? abstrahlwinkel bei 50 % i v : 120 applications anwendungen ? downlights ? downlights ? general lighting ? allgemeinbeleuchtung
2012-04-10 preliminary data 2 draft version 0.0 gw kajrb2.em ordering information bestellinformation type color temperature luminous flux 1) page 17 ordering code typ farbtemperatur lichtstrom 1) seite 17 bestellnummer i f = 600 ma (k) v (lm) gw kajrb2.em-sttq-27h4 270 0 2400 ... 3300 q65111a2515 gw kajrb2.em-sutq-30h4 300 0 2590 ... 3300 q65111a2516 gw kajrb2.em-tptr-40h4 4000 2800 ... 3590 q65111a2517 gw kajrb2.em-tptr-50h4 5000 2800 ... 3590 q65111a2518 gw kajrb2.em-tptr-57h4 5700 2800 ... 3590 q65111a2519 gw kajrb2.em-tptr-65h4 6500 2800 ... 3590 q65111a2520 note: the above type numbers represent th e order groups which include only a few bri ghtness groups (see page for explanation). only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). e. g. gw kajrb2.em-tptr-40h4 means t hat only one group tp, tq, tr will be shippable for any packing unit. in order to ensure availability, single brightness groups will not be orderable. in a similar manner for colors where color chromaticity coor dinate groups are measured and binned, single groups will be shippe d on any one packing unit. gw kajrb2.em-tptr-40h4 means that the device will be shipped with in the specified limits as stated on page in order to e nsure availability, single color chromaticity groups groups w ill not be orderable (see page for explanation). anm.: die oben genannten typbezeic hnungen umfassen die bestellbaren selektionen. diese bestehen aus wenigen helligkeitsgruppen (siehe seite fr n?here informationen). es wird nur eine einzige helligkeitsgrup pe pro verpackungseinheit geliefert. z. b. gw kajrb2.em-tptr-40h 4 bedeutet, dass in einer verpackungseinheit nur eine der helligkeitsgruppen tp , tq, tr enhalten ist. um die liefersicherheit zu gew?hrleis ten, k?nnen einzelne helligkeitsgruppen nicht bestellt werden. gleiches gilt fr die farben, bei denen farbortgruppen gemessen und gruppiert werden. pro verpackungseinheit wird nur eine farb ortgruppe geliefert. z.b. gw kajrb2.em-tptr-40h4 bedeutet, dass in einer ve rpackungseinheit nur eine der fa rbortgruppen enthalten ist (si ehe seite fr n?here informationen). gw kajrb2.em-tptr- 40h4 bedeutet, dass das bauteil innerhalb der auf seite spezifiz ierten grenzen gelief ert wird. um die liefersicherheit zu gew?hr leisten, k?nnen einzelne farbortgruppen nicht bestellt werden.
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 3 maximum ratings grenzwerte parameter symbol values unit bezeichnung symbol werte einheit operating temperature range betriebstemperatur t op -30 ... 85 c storage temperature range lagertemperatur t stg -40 ... 100 c junction temperature sperrschichttemperatur t j 125 c forward current durchlassstrom (t s = 25 c) i f 1080 ma surge current sto?strom (t <= 10 s; d = 0.005; t s = 25 c) i fm 1600 ma reverse voltage sperrspannung (t s = 25 c) v r not designed for reverse operation v
2012-04-10 preliminary data 4 draft version 0.0 gw kajrb2.em characteristics (t s = 25 c; i f = 600 ma) kennwerte parameter symbol values unit bezeichnung symbol werte einheit viewing angle at 50 % i v abstrahlwinkel bei 50 % i v typ. 2 ? 120 forward voltage 2) page 17 durchlassspannung 2) seite 17 min. typ. max. v f v f v f 40 44 48 v v v reverse current sperrstrom i r not designed for reverse operation real thermal resistance junction / solder point realer w?rmewiderstand sperrschicht / l?tpad typ. max. r th js real r th js real 0.40 0.45 k/w k/w "electrical" thermal resistance junction / solder point "elektrischer" w?rmewiderstand sperrschicht / l?tpad (with efficiency e = 20 %) typ. r th js el 0.32 k/w
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 5 efficiency comparison table, cct = 4000k 5) page 17 effizienz-vergleichstabelle 5) page 17 brightness groups helligkeits-gruppierungsschema forward current / forward current forward voltage / durchlass- spannung luminous flux / lichtstrom optical efficiency / optischer wirkungs- grad forward voltage / durchlass- spannung luminous flux / lichtstrom optical efficiency / optischer wirkungs- grad t s = 25 c t s = 25 c t s = 25 c t s = 85 c t s = 85 c t s = 85 c i f (ma) typ. v f (v) typ. v (lm) typ. (lm/w) typ. v f (v) typ. v (lm) typ. (lm/w) 200 39.8 1080 136 38.6 950 123 350 41.6 1835 126 40.3 1615 114 500 43.1 2550 118 41.8 2245 107 600 44.0 3000 114 42.7 2640 103 700 45.0 3430 109 43.6 3020 99 1000 47.6 4630 97 46.1 4075 88 group luminous flux 1) page 17 luminous flux 1) page 17 luminous flux 3) page 17 luminous flux 3) page 17 gruppe lichtstrom 1) seite 17 lichtstrom 1) seite 17 lichtstrom 3) seite 17 lichtstrom 3) seite 17 t s = 25 c t s = 25 c t s = 85 c t s = 85 c min. v (lm) max. v (lm) extrapolated min. v (lm) extrapolated max. v (lm) st 2400 2590 2150 2320 su 2590 2800 2320 2510 tp 2800 3040 2510 2725 tq 3040 3300 2725 2960 tr 3300 3590 2960 3220 note: the standard shipping format for serial types includes either a lower family group, an up per family group or a grouping o f all individual brightness groups of only a few brightne ss groups. individual brightness groups cannot be ordered. anm.: die standardlieferform von serienty pen beinhaltet entweder eine untere familieng ruppe, eine obere familiengruppe oder ein e sammelgruppe, die aus nur wenigen helligkeitsgruppen bestehen. einz elne helligkeitsgruppen sind nicht bestellbar.
2012-04-10 preliminary data 6 draft version 0.0 gw kajrb2.em chromaticity coordinate groups 4) page 17 farbortgruppen 4) seite 17
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 7 group name on label gruppenbezeichnung auf etikett example: st-40h4 beispiel: st-40h4 brightness helligkeit chromaticity coordinate group farbortgruppe st 40h4 note: no packing unit / tape ever contai ns more than one group for each selection. anm.: in einer verpackungseinheit / gurt ist immer nur eine gruppe fr jede selektion enthalten.
2012-04-10 preliminary data 8 draft version 0.0 gw kajrb2.em relative spectral emission - v( ) = standard eye response curve 5) page 17 , 1) page 17 relative spektrale emission - v( ) = spektrale augenempfindlichkeit 5) seite 17 , 1) seite 17 e rel = f ( ); t s = 25 c; i f = 600 ma radiation characteristics 5) page 17 abstrahlcharakteristik 5) seite 17 i rel = f ( ? ); t s = 25 c 42s 350 400 450 500 550 600 650 700 750 800 [nm] 0.0 0.2 0.4 0.6 0.8 1.0 e rel : w hi t e : v 2700 6500 0 0.2 0.4 1.0 0.8 0.6 ? 1.0 0.8 0.6 0.4 0? 10? 20? 40? 30? ohl01660 50? 60? 70? 80? 90? 100? 0? 20? 40? 60? 80? 100? 120?
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 9 forward current 5) page 17 durchlassstrom 5) seite 17 i f = f (v f ); t s = 25 c relative luminous flux 5) page 17 relativer lichtstrom 5) seite 17 v / v (600 ma) = f(i f ); t s = 25 c chromaticity coordinate shift 5) page 17 farbortverschiebung 5) seite 17 cx, cy = f(i f ); t s = 25 c 42ui5010806 36 38 40 42 44 46 48 u f [v] 200 400 600 800 1000 i f [a] 42ib15010806 0 200 400 600 800 1000 i f [a] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 v v (600 ma ) gw kajrb2.em 200 400 600 800 1000 i f [ma] -0.03 -0.02 -0.01 0.00 0.01 0.02 0.03 cx cy : c x 2700k : c y 2700k : c x 6500k : c y 6500k
2012-04-10 preliminary data 10 draft version 0.0 gw kajrb2.em relative forward voltage 5) page 17 relative vorw?rtsspannung 5) seite 17 v f = v f - v f (25c) = f(t j ); i f = 600 ma relative luminous flux 5) page 17 relative lichtstrom 5) seite 17 v / v (25 c) = f(t j ); i f = 600 ma chromaticity coordinate shift 5) page 17 farbortverschiebung 5) seite 17 cx, cy = f(t j ); i f = 600 ma gw kajrb2.ec -20 0 20 40 60 80 100 t j [c] -2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0 2.5 u f [v] gw kajrb2.ec -20 0 20 40 60 80 100 t j [c] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 v v (25 c ) gw kajrb2.ec -20 0 20 40 60 80 100 t j [c] -0.03 -0.02 -0.01 0.00 0.01 0.02 0.03 cx cy : cx 2700k : cy 2700k : cx 6500k : cy 6500k
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 11 max. permissible forward current maximal zul?ssiger durchlassstrom i f = f (t) permissible pulse handling capability zul?ssige impulsbelastbarkeit i f = f(t p ) duty cycle d = parameter, t s = 25 c ... 85 c gw kajrb2.ec 020406080 t s [c] 0 200 400 600 800 1000 1200 i f [ma] : t s gw kajrb2.ec 10 -5 10 -4 10 -3 0.01 0.1 t p [s] 1.0 1.2 1.4 1.6 i f [a] : d = 1,0 : d = 0,5 : d = 0,2 : d = 0,1 : d = 0,05 : d = 0,02 : d = 0,01 : d = 0,005
2012-04-10 preliminary data 12 draft version 0.0 gw kajrb2.em package outline 6) page 17 ma?zeichnung 6) seite 17 approximate weight: 9.36 g gewicht: 9.36 g
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 13 tray bauteiltr?ger 20 units per tray, 5 trays per vacuum bag barcode-product-label (bpl) barcode-produkt- etikett (bpl) oha0456 3 (g) group: 1234567890 (1t) lot no: (9d) d/c: 1234 (x) prod no: 123456789 (6p) batch no: 1234567890 lx xxxx rohs compliant bin1: xx-xx-x-xxx-x ml 2 temp st 260 c r pack: r18 demy 022 b_r999_1880.1642 r 9999 (q)qty: semiconductors osram opto xx-xx-x-x
2012-04-10 preliminary data 14 draft version 0.0 gw kajrb2.em transportation pack ing and materials kartonverpackung und materialien dimensions of transportation box in mm (inch) note: moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. regarding dry pack you will find further information in the internet and in the short form catalog in chapter ?tape and reel? under the topic ?dry pack?. here you will also find the normative references like jedec. anm.: feuchteempfindliche produkte sind verpackt in einem trockenbeutel zusammen mit einem trockenmittel und einer feuchteindikatorkarte. bezglich trockenverpackung finden sie weitere hinw eise im internet und in unserem short form catalog im kapitel ?gurtung und verpackung? unter dem punkt ?trockenverpackung?. hier sind normenbezge, unter anderem ein auszug der jedec-norm, enthalten. width / breite length / l?nge height / h?he 284 3 (11,181 0,118) 268 3 (10,551 0,118) 55 3 (1,575 0,118)
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 15 notes hinweise the evaluation of eye safety occurs according to the standard iec 62471:2006 ("photobiological safety of lamps and lamp systems"). within the risk grouping system of this cie standard, the led specified in this data sheet fall into the class low risk (exposure time 100s). under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. as a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. as is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. die bewertung der augensicherheit erfolgt nach dem standard iec 62471:2006 ("photobiological safety of lamps and lamp systems"). im risikogruppensystem dieser cie- norm erfllen die in diesem datenblatt angegebenen leds folgende gruppenanforderung - low risk (expositionsdauer 100s). unter realen umst?nden (fr expositionsdauer, augenpupille, betrachtungsabstand) geht damit von diesen bauelementen keinerlei augengef?hrdung aus. grunds?tzlich sollte jedoch erw?hnt werden, dass intensive lichtquellen durch ihre blendwirkung ein hohes sekund?res gefahrenpotenzial besitzen. nach einem blick in eine helle lichtquelle (z.b. autoscheinwerfer), kann ein tempor?r eingeschr?nktes sehverm?gen oder auch nachbilder zu irritationen, bel?stigungen, beeintr?chtigungen oder sogar unf?llen fhren.
2012-04-10 preliminary data 16 draft version 0.0 gw kajrb2.em disclaimer disclaimer osram os assumes no liability whatsoever for any use of this document or its content by recipient including, but not limited to , for any design in activities based on this preliminary draft version. osram os bernimmt keine wie auch immer geartete haftung fr die nutzung dieses dokuments und seines inhaltes durch den empf?nger, insbesondere nicht fr irgendwelche design-aktiv it?ten, die auf dieser vorl?ufigen entwurfsversion basieren osram os beh?lt sich beispielsweise auch vor, jederzeit die weiter- und fertigentwicklung des zugrundeliegenden designs einseitig einzustellen. attention please! the information describes the type of component and shall not be considered as assured char acteristics. terms of delivery and rights to change design reserved. due to technical requirements components may contain dangerous substances. for information on the types in question please contact our sales organization. if printed or downloaded, please find the latest version in the internet. packing please use the recycling oper ators known to you. we can also help you ? get in touch with your nearest sales office. by agreement we will take packing material back, if it is sorted. you must bear th e costs of transport. for packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. components used in life-support devices or systems must be expressly authorized for such purpose! critical components* may only be used in life-support devices** or systems with th e express written approval of osram os. *) a critical component is a component used in a life-support device or system whose failure can reasonably be expected to ca use the failure of that life-support device or system, or to affect its safety or the effectiveness of th at device or system. **) life support devices or systems are intended(a) to be implanted in the human bo dy,or(b) to support and/or maintain and sustain human life.if they fail, it is reasonable to assume that th e health and the life of the user may be endangered. bitte beachten! lieferbedingungen und ?nderungen im design vorbehalten. aufgrund technischer anforderungen k?nnen die bauteile gefahrstof fe enthalten. fr weitere informationen zu gewnsch ten bauteilen, wenden sie sich bitte an unseren vertrieb.falls sie diese datenblatt ausgedruckt oder herunterge laden haben, finden sie die aktuellste version im internet. verpackung benutzen sie bitte die ihnen bekannten recyclingwege. wenn diese ni cht bekannt sein sollten, wenden sie sich bitte an das n?chstgelegene vertriebsbro. wir nehmen das verpackungsmaterial zurck, falls dies vereinbart wurde und das material sortiert ist. sie tragen die transportkosten. fr verpackungsmaterial, das unsortiert an uns zurckgeschickt wird oder das wir nicht annehmen mssen, stellen wir ihnen die anfallenden kosten in rechnung. bauteile, die in lebenserhaltenden apparaten und systemen eingesetzt werden, mssen fr diese zwecke ausdrcklich zugelassen sein! kritische bauteile* drfen in lebenserhaltenden apparaten und systemen nu r dann eingesetzt werden, wenn ein schriftliches einverst?ndnis von osram os vorliegt. *) ein kritisches bauteil ist ein bauteil, das in lebenserhaltenden appa raten oder systemen eingesetzt wird und dessen defekt voraussichtlich zu einer fehlfunktion dieses lebenserhaltenden apparates oder systems fhren wird oder die sicherheit oder effektivit?t dieses apparates oder systems beeintr?chtigt. **) lebenserhaltende appara te oder systeme sind fr (a) die implantierung in de n menschlichen k?rper oder (b) fr die lebenserhaltung bestimmt. falls sie versagen, kann davon ausgegangen werden, dass die gesundheit und das leben des patienten in gefahr ist.
draft version 0.0 gw kajrb2.em 2012-04-10 preliminary data 17 glossary glossar 1) brightness : brightness groups are tested at a current pulse duration of 25 ms and a tolerance of 11%. 1) helligkeit : helligkeitswerte werden mit einer stromeinpr?gedauer von 25 ms und einer genauigkeit von 11% ermittelt. 2) forward voltage : forward voltages are tested at a current pulse duration of 1 ms and a tolerance of 0.1 v. 2) durchlassspannung : spannungswerte werden mit einer stromeinpr?gedauer von 1 ms und einer genauigkeit von 0,1 v ermittelt. 3) extrapolated values : the stated values are extrapolated data. these are based on the testing limits measured as specified in the datasheet. the extrapolation is based on the typical temperature and forward current dependence shown in the datasheet graphs. 3) extrapolierte werte : bei den angegebenen werten handelt es sich um extrapolierte angaben. diese basieren auf den im datenblatt spezifizierten testgrenzen bei den angegebenen messbedingungen. die extrapolation erfolgte anhand der im datenblatt angegebenen typischen diagramme zur temperatur- und stromabh?ngigkeit. 4) chromaticity coordinate groups : chromaticity coordinate grou ps are tested at a current pulse duration of 25 ms and a tolerance of 0.01. 4) farbortgruppen : farbortgruppen werden mit einer stromeinpr?gedauer von 25 ms und einer genauigkeit von 0,01 ermittelt 5) typical values : due to the special conditions of the manufacturing processes of led, the typical data or calculated correlations of technical parameters can only reflect statistical figures. these do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. if requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 5) typische werte : wegen der besonderen prozessbedingungen bei der herstellung von led k?nnen typische oder abgeleitete technische parameter nur aufgrund statistischer werte wiedergegeben werden. diese stimmen nicht notwendigerweise mit den werten jedes einzelnen produktes berein, dessen werte sich von typischen und abgeleiteten werten oder typischen kennlinien unterscheiden k?nn en. falls erforderlich, z.b. aufgrund technischer verbesserungen, werden diese typischen werte ohne weitere ankndigung ge?ndert. 6) tolerance of measure : dimensions are specified as follows: mm (inch). 6) ma?toleranz : ma?e werden wie folgt angegeben: mm (inch). published by osram opto semiconductors gmbh leibnizstra?e 4, d-93055 regensburg www.osram-os.com ? all rights reserved.


▲Up To Search▲   

 
Price & Availability of GWKAJRB2EM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X